Project Category: <span>IMPIANTI</span>
REFRIGERATING PLANT
Dimensioning of the refrigerated water requirements of machinery. We have supplied a chiller, a storage tank and the pumps feeding the various machines.
2 ATU, FLOW CAPACITY 21,000 m3/H, FOR COOLING ELECTRICAL PANELS
2 ATU for cooling electrical panels
MISCELLANEOUS WATER FILTERS
MISCELLANEOUS WATER FILTERS
TUBING FOR WET ABATEMENT SYSTEM 90,000 m3/H
Fume extraction system from furnaces at 200-300° C with dilution for lowering temperature. Total flow capacity 90,000 m3/h. Welded piping in stainless steel AISI316 with flare flat flanges. D.1,250 mm Food industry
ATTENUATORS FOR WET ABATEMENT SYSTEM 90,000 m3/h
rectangular attenuators in stainless steel sheet AISI 316 on washing towers exhaust, 45,000 m3/h each sizes 1800 × 1800 x L 2000 mm rock wool splitters 200 mm thick
WET ABATEMENT SYSTEM 90,000 m3/H
Fume extraction system from furnaces at 200-300° C with dilution for lowering temperature. Odor abatement through two water wash tower, with chemical treatment. Total flow capacity 90,000 m3/h. Food industry
ACTIVATED CARBON FILTER 12,000 m3/H
Activated carbon filter of 12,000 m3/h on waste disposal lines
ACTIVATED CARBON FILTER 20,000 m3/H
Activated carbon filter of 20,000 m3/h with wet pre-abatement and drying on cosmetic production line
ACTIVATED CARBON FILTER 15,000 m3/H
Activated carbon filter of 15,000 m3/h on ink production lines